ECG Machine Six Channel

Model: 600g
product img

 

INTRODUCTIONS:

ECG600G is an Electrocardiograph which can collect 12-lead ECG signal simultaneously and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, case database management

Main Features

1)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
2)Real-time and continuously record clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
3)Full-digital filter design, anti-baseline drift, AC and EMG interference.
4)Adjust the baseline automatically, optimize the print setting and optional rhythm leads.
5)In AUTO mode, finish recording by pressing the button once, which improves work efficiency.
6)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
7)With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden and improves work efficiency.
8)Sync collection for 12-lead ECG, multiply printing formats, including 2×6+1(rhythm lead), 2×6, 3×4, 3×4+1(rhythm lead), 4×3, 4×3+1(rhythm lead), 6×2, 6×2+1(rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc.
9)Display of real-time 3/6/12-lead ECG, "Lead off" and "Lack of paper" on one screen, and with ECG DEMO mode. Auto-check and auto-analysis for ECG parameters, ECG waveform can be recorded manually or automatically. And patient information can be stored by case database.
10)Time print can be set to every 1/2/3/5/10/20/30/60 minutes.
11)Print setting, including “Print and save”(print waveform and save case), “Print no save”(only print waveform but not save case), “Save no print”(only save case but not print waveform).
12)AC/DC, built-in rechargeable lithium battery and auto-protection circuit, and automatic power off when there is no operation in appointed time.
13)Store more than 1000 cases, convenient for case review and statistic.

 

Specifications:

  • Input Way: Floating Defibrillation Protection
  • Lead: Standard 12 Leads
  • Patient Leak Current: <10 µA
  • Input Independence: ≥50 M
  • Frequency response: 0.0 Hz~150 Hz(-3dB)
  • Time constant: Time constant >3.2s
  • CMRR: >60dB, >100dB (Adding filter)
  • EMG Interference filter: 35 Hz_ -3d B
  • Recording Way: Thermal Printing System
  • Recording Paper Specification: 210 mm(W) x 20 mm(L) high-speed thermal paper
  • Paper Speed: Auto record: 25mm/s, 50mm/s, error ± 5 %
  • Rhythm record: 25mm/s, 50mm/s,error ± 5 %
  • Manual record: 5mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s error ± 5 %
  • Sensitivity Selections: 5, 10, 20, 40 mm/mV, error ± 5 % standard sensitivity is 10 mm/mV 0.2 mm/mv,
  • Auto Record: Record Setup according to auto record format & mode, automatically change leads measuring & analysis
  • Rhythm Record: Record Setup according to auto record format & mode, automatically change leads measuring & analysis
  • Manual Record: Record Setup according to manual record format, manually changing leads
  • Measurement Parameters: HR, P-R interval, P Duration, QRS duration, Q Interval, Q-Tc, P Axis, T Axis, R(VS), S(V), R(V5)+S(V1)
  • Product Safety Type: Class 1 CF applied part ; there is defibrillation & placing protection circuit in
  • Enduring Polarization Voltage: ± 5500mV
  • Noise Level: _< 15u VP-p
  • Size: 334 mm(L) x 320 mm(W) x 85 mm(H)
  • Power Supply / frequency: AC: 100-240V, 50/60 Hz DC :14.8 V, 3700 mAh rechargeable lithium battery

 

Product Details:

Number of Channels 12
Machine Type Digital
Brand Contec
Model ECG-1200G
Operating Mode Automatic
Filters Type Emg Filter