Patient Monitor JPD-800B (12.1inch)

Brand Model: JPD-800B
product img

Key Specifications/Special Features:

  • Name: 12'' patient monitor
  • Model: JPD-800B(12'')
  • Functions:
  1. 6 display interface
  2. Basic standard(six parameter): ECG, SpO2, NIBP, PR, RESP, temp
  3. CE marked
  4. 720 hours trend data storage, 12 hours waveform review
  5. Sounds, voice and light alarm. ST segment can be adjusted
  6. Support nurse call system. Lithium battery (built-in)
  • Features:
  • 12.1-inch high resolution color TFT LCD display
  • One level menu, easy to use
  • Maximum 720 hours tabular and graphic trends of all parameters
  • Built-in thermal recorder and two batteries capacity
  • Suitable for adult, pediatric, neonatal patient
  •  Type Arrhythmic analysis, ST segment analysis, pacemaker detection anti-ESU, anti-defibrillator
  • OxyCRG dynamic view and short trend coexist display, nurse call system. Standard network interface, can be connected to the central monitoring system
  • Packaging:
  • Product dimension: 305mm*275mm*150mm, net weight: 3.6kg
  • Packaging: Carton size: 370mm*230mm*442mm 1PCS/CTN gross weight: 6.4kg
  • Or carton size: 482mm*385mm*465mm 2PCS/CTN gross weight: 13.8kg
  • Specifications:
  • 12.1-inch TFT; resolution: 800*600
  • ECG, SpO2, PR, NIBP, RR, Temp
  • Operating condition
  • Working storage:
  • Temperatures: 040 -20-70 Centigrade degrees
  • Humidity range: 15-95%, 10- 90%
  • Power supply: External power requirement: AC 100-250V 50/60Hz
  • Classification:
  • Anti-electroshock type class I equipment
  • Anti-electroshock degree CF defibrillation
  • Accordant standard: GB9706.1: 1995/GB/T14710: 1993/YY0089: 1992/YY91079: 1999
  • Parameter:
  • ECG
  • Leads mode: 5 leads: I, II, III, AVR, Avl, Avf, V
  • Gain(mm/mV): 1/4, 1/2, 1, 2, 4
  • Scanning speed: 12.5mm/s, 25mm/s, 50mm
  • Frequency response: Diagnosis 0.05-130Hz
  • Monitoring 0.5 40Hz. Operation 1.0- 20Hz. Heart rate range: 15-350BPM. Heart rate accuracy: ± 1%. ST segment analysis: -0.8-+0.8Mv. ST segment accuracy: ± 0.02Mv
  • NIBP
  • Measure and alarm range
  • Adult mode: SYS 40~280 mmHg/DIA 10 ~ 220 mmHg/MEAN 20~240 mmHg
  • Pediatric mode: SYS 40~220 mmHg/DIA 10 ~ 160 mmHg/MEAN 20~170 mmHg
  • Neonatal mode: SYS 40~135 mmHg/DIA 10 ~ 100 mmHg/MEAN 20~110 mmHg
  • Static pressure range: 0~300 mmHg
  • Static pressure accuracy: ± 3 mmHg or 2%
  • Resolution: 1 mmHg
  • Protection mode: Dual over voltage protection
  • SpO2:
  • Measure range: 1-100%. Accuracy: ± 2% (70-100%). Resolution: 1%
  • Pulse rate:
  • Measure range: 20-300 BPM. Accuracy: ± 2 BPM. Resolution: 1 BPM
  • Temperature:
  • Channel: 2. Measure range: 0-50 Centigrade degrees